$12,420.00
Proceq's Equotip 550 Leeb D and UCI HV1-HV10 hardness tester tests on-site heavy, large or installed parts and fine-grained materials with any shape in addition to heat-treated surfaces. This model will also work with Rockwell testing but you need to purchase an additional probe for that application.
Features on-screen feedback which reduces measurement inaccuracies which can be caused by human error. The Proceq Equoptip 550 includes ready-to-go reports through powerful built-in reporting. Extremely durable touchscreen with enhanced software features and analysis functions.
Equotip 550 Portable Leeb D and UCI HV1-HV10 Hardness Tester takes advantage of a new generation full color, dual processor Touchscreen Unit with enhanced software capabilities. The instrument offers a unique range of functions which ultimately help speed up on-site and laboratory inspections and analysis.
Features:
Instrument Firmware |
Automatic compensation for impact direction |
PC Software |
Equotip Link allowing direct reporting and custom reports |
Display |
7” color rugged touchscreen unit (800 x 480 pixels) with dual core processor |
Memory |
Internal 8 GB flash memory (> 1’000’000 measurements) |
Connections |
USB host / device and Ethernet |
Leeb D Features:
Wide Measurement Range |
Leeb D impact devices are best suited for on-site testing of heavy, large or already installed parts. |
Broad Hardness Scales Coverage |
The measurements are automatically converted to all common hardness scales (HV, HB, HRC, HRB, HRA, HS) as required. |
Impact Devices & Accessories |
Proceq offers a wide variety of impact devices along with support rings to serve most hardness testing requirements. |
Test Blocks Portfolio |
Extensive range of precise hardness test blocks available for each impact device with different hardness levels for regular verification. |
UCI HV1-HV10 Features:
Adjustable test load |
The required test load can be selected by the user in the settings menu. For each measurement series, the force can be chosen from ten levels between HV1 and HV10, to fit a wide range of applications. The minimum required mass for reliable UCI measurements is 0.3 kg (0.66 lbs), and a thickness of at least 5 mm (0.2 inch). Examples: HV1 - Precision parts, thin coatings, hardened layers |
Optional Special Foot |
The optionally available special foot increases the measurement repeatability. It can be used for flat or curved surfaces. For curved surfaces there are two different apertures, one for diameters from 5 to 25 mm and one for larger diameters from 20 to 70 mm. |
Applications:
Standard to large objects |
Yes |
Round objects |
Yes and In combination with support rings |
Light objects |
Yes and with impact device Leeb C |
Very hard objects |
Yes and with impact devices Leeb S and E |
Cast objects |
With impact device Leeb G (Not with UCI) |
Polished objects |
Yes and with impact device Leeb C |
Limited accessibility |
With impact devices Leeb DC and DL (Not with UCI) |
Thin objects |
No |
Heat treated surfaces |
Yes |
Additional Applcations: |
Fire damage assessment |
Proceq Equotip Leeb D Model Specifications
Native Scale |
HL |
Measuring Range |
150 - 950 HL |
Measuring Accuracy |
± 4 HL (0.5% at 800 HL) |
Available Scales |
HB, HV, HRA, HRB, HRC, HS, MPA |
Available Probes |
Leeb D / DC / DL / S / E / G / |
Combination With Other Methods |
Portable Rockwell, UCI |
Average Roughness Ra (µm / µinch) |
7 / 275 (Leeb G) |
Minimum Mass (kg / lbs) |
0.02 / 0.045 (Leeb C) |
Minimum Thickness (mm / inch) |
1 / 0.04 (Leeb C) |
Leeb D Standards & Guidelines
Standards ASTM A 956 |
Guidelines ASME CRTD-91 |
Native Scale |
HV (UCI) |
Measuring Range |
20 - 2000 HV |
Measuring Accuracy |
± 2% (150 - 950 HV) |
Available Scales |
HB, HV, HRA, HRB, HRC, HR15N, HR15T, MPA |
Available Probes |
UCI (Adjustable HV1 - HV10) |
Combination With Other Methods |
Leeb, Portable Rockwell |
Average Roughness Ra (µm / µinch) |
12.5 / 500 |
Minimum Mass (kg / lbs) |
0.3 / 0.66 |
Minimum Thickness (mm / inch) |
5 / 0.2 |
UCI HV1-HV10 Standards & Guidelines
Standards DIN 50159 |
Guidelines ASME CRTD-91 |
Equotip 550 Unit Specifications
Display |
7” color display 800x480 pixels |
Memory |
Internal 8 GB flash memory |
Regional Settings |
Metric and Imperial units, multi-language and timezone supported |
Power Input |
12 V +/-25 % / 1.5 A |
Connectors |
Probe, USB host / device and Ethernet |
Dimensions |
250 x 162 x 62 mm |
Weight |
1525 g (incl. Battery) |
Battery |
3.6 V, 14.0 Ah |
Battery Lifetime |
> 8 h (in standard operating mode) |
Humidity |
< 95 % RH, non condensing |
Operating Temperature |
-10 °C to +50 °C |
IP |
54 |
Certification |
CE |